TC-5955APU Pneumatic Shield Box Key Benefits
- Reliable High RF Shielding up to 12 GHz
- Designed for long life and ease of maintenance
- Specifically designed for various types of mobile devices
- Pneumatic Control of Lid Open-Close
- Absorbing materials for stable measurement results
- EMI filters on all data ports and power line
- RS-232C Remote Control Operations Feature
The TC-5955APU pneumatic Shield Box is ideal for testing up to 12GHz in a high volume environment. The Pneumatic RF Shield Box provides remote operations features as well as local control, making it highly versatile. Pair the RF Shield Box with one of our QRH and the DPVA antennas to complete your testing configuration. Why stop there, add a custom fixture to hold your DUT to maximize your testing repeatability. Ask about our custom test fixturing services for a completely integrated solution.
*SPECIFICATIONS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE
Specifications
TC-5955APU Pneumatic Shield Box Specifications
- Basic RF Connector: 16, N(f) outside to SMA (f) inside
- Basic Data Connector: none
- Remote Control: RS-232C, Dual Remote Switch
- Air Connector:
- Main Connector:6 mm OD hose, one-touch fitting
- Input Air Pressure: 5 to 10 bar
- Dimensions
- Outer Dimension: 534(W) x 526(D) x 583(H) mm Door Closed, 786(D) mm Door Open
- Door Size:176(W) x 130(H) mm
- Door Stroke (Open/Close): 260 mm
- Weight: approx. 39 kg
- Packing
- Size: 676(W) x 636(D) x 699(H) mm
- Weight: approx. 46 kg
*The size or weight of a package may vary on how to pack a package.
Typical RF Shielding
Typical RF Shielding
The shield effectiveness below is measured when the blank panel is mounted; other I/O interface panel results a different shielding effectiveness of the shield box.
- 100 to 3000 MHz > 70 dB
- 3000 MHz to 12GHz > 60 dB
Custom Configurations
TC Manual RF Shield Box Custom I/O Interface Panel
Customized I/O Interface panels are available. Please contact the CTS sales team for more information
I/O Interface | Order Number | Typical Data Rate/Line Voltage | Typical Shielding* |
DB37, 1000pF pi Filter | 3409-0012-1 | 3 Mbps / 100 VDC,
5 Amps max | >70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz |
DB25, 1000pF pi Filter | 3409-0009-1 | 3 Mbps / 100 VDC,
5 Amps max | >70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz |
DB25, 100pF pi Filter | 3409-0014-1 | 10 Mbps / 100 VDC,
5 Amps max | >50 dB from 0.5 to 2 GHz
>60 dB from 2 to 3 GHz
>60 dB from 3 to 6 GHz |
DB9, 1000pF pi Filter | 3409-0008-1 | 3 Mbps / 100 VDC,
5 Amps max | >70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz |
DB9, 100pF pi Filter | 3409-0010-1 | 10 Mbps / 100 VDC,
5 Amps max | >50 dB from 0.5 to 2 GHz
>60 dB from 2 to 3 GHz
>60 dB from 3 to 6 GHz |
USB 2.0 Filter | 3409-0018A-3 | 480 Mbps / 5 V, 500 mA /
Max Current: 5A | >60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz |
USB 3.0 Filter(Active) | 3409-0042A-1 | 5000 Mbps / 5 V, 900 mA /
Max Current: 1.5 A | >70 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>55 dB from 3 to 6 GHz |
RJ-45 Filter | 3409-0022A | 1 Gbit/s Copper-Line
Ethernet (1000 BASE-T) | >60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz |
DC Power Adaptor | 3406-0004A | 50 VDC,
3 Amps max | >70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>80 dB from 3 to 6 GHz |
DC Power Adaptor,
Banana Jack Type | 3406-0005A
3406-0006A | 50 VDC,
10 Amps max | >70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>80 dB from 3 to 6 GHz |
AC Power Adaptor | 3103-0009A | 250 VAC,
7 Amps max | >70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>80 dB from 3 to 6 GHz |
RF, N-SMA Connector | 3408-0038 | | >60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz |
RF, SMA-SMA Connector | 3408-0039 | | >60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz |
*SPECIFICATIONS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE
- Each shielding effectiveness is measured when each I/O interface panel, which is shown above, is mounted.
- Above data was measured by Tescom, The Shielding Effectiveness might be different based on the measuring method and condition.
- This data has been measured under the condition that the cables are not connected to each filters. When the cables are connected it can affect the shielding performance.