TC-5910DP Pneumatic RF Shield Box

Provides RF shield and signal connections necessary for testing mobile wireless devices, such as mobile cell phones. The TC-5910DP RF Shield box now has a an optional I/O module that’s replaceable so it can be easily changed as your interface requirements change . With the RF coupling accessories and filtered control ports, the TC-5910DP makes an ideal solution for RF testing mobiles and small RF devices on test benches for R&D, Service, and QA.

Request Quote Download Data Sheet

SKU: TC-5910DP Categories: , ,

Description

The TC-5910DP Pneumatic RF Shield Box is engineered for automated wireless device testing in demanding production and laboratory environments. This pneumatic RF shielded enclosure provides strong RF isolation while supporting fast, repeatable test cycles.

Designed for high-throughput manufacturing, the TC-5910DP uses a pneumatic lid mechanism to ensure consistent sealing pressure during each operation. As a result, it delivers dependable signal containment and reduces variability caused by external RF interference.


Reliable RF Isolation with Dual Pneumatic Control

The TC-5910DP Pneumatic RF Shield Box features dual pneumatic control for precise lid operation and fixture integration. This design improves automation efficiency and ensures stable enclosure performance during continuous production testing.

Because accurate RF validation depends on controlled environments, this shielded enclosure minimizes signal leakage and outside interference. Therefore, engineers can confidently test Wi-Fi, Bluetooth, cellular, and IoT devices with improved measurement consistency.

The system also supports integration into automated test stations and robotic production setups. Its durable construction makes it suitable for both engineering labs and high-volume manufacturing lines.


Flexible Integration for Wireless Test Applications

The TC-5910DP is designed to accommodate customizable I/O configurations. Engineers can configure RF connectors, filtered power lines, and data interfaces based on specific device requirements.

In addition, the enclosure supports automated workflows by maintaining consistent DUT positioning during each test cycle. This reduces operator adjustments and improves overall efficiency.

For related shielding and filtering solutions, explore:

RF Shield Boxes: https://ctscorp-usa.com/rf-shield-boxes/
RF Feedthrough Filters: https://ctscorp-usa.com/rf-feedthrough-filters/

For regulatory reference, manufacturers often consult:
Federal Communications Commission (FCC): https://www.fcc.gov
IEEE Standards Association: https://standards.ieee.org

Additional information

Weight 8 kg
Dimensions 9.25 × 5.1 × 5.4 in
Function

Pneumatic

Internal Depth

0-10in

Internal Height

0-6in

Internal Width

0-8in

Manufacturer

Tescom

Specifications

RF Shield Box TC-5910DP Specifications

  • Line Voltage: DC 24V, Max. 2A
  • Remote Control: RS-232C, 3 wire, DB9(s)
  • Air Connection:
    • Main Connector: 6mm OD hose, one-touch push-on fitting
    • Fixture Control Connector: 4mm OD hose, one-touch, push-on fitting
    • Input Air Pressure: 5 to 10 bar
  • Dimensions:
    • Inner Dimension: 130(W) x 235(L) x 138(H) mm
    • Outer Dimension: 342(W) x 239(L) x 262(H) mm, lid closed; 355(H) mm, lid open
    • Weight: approx. 7 kg
  • Packing:
    • Size: 365(W) x 450(D) x 280(H) mm
    • Weight: 8 kg

    *The size or weight of a package may vary on how to pack a package.

  • Accessories Included:
    • Test Report
    • RF Cable, RG-400S, N(m) to N(m) 1 m, 1 pc
    • DATA Cable, DB9(s) to DB9(s) 2 m, 1 pc
    • Air Coupler, 1 pc
    • Switching Power Supply, 1 pc

Typical RF Shielding

Typical RF Shielding

The shield effectiveness below is measured when the blank panel is mounted; other I/O interface panel results a different shielding effectiveness of the shield box.
  • 100 to 2000 MHz > 70 dB
  • 2000 to 3000 MHz > 70 dB
  • 3000 to 6000 MHz > 50 dB

***Isolation example above is based on I/O configuration as specified above. Isolation may be higher or lower based on specific I/O configuration installed.

Custom Configurations

TC Manual RF Shield Box Custom I/O Interface Panel

Customized I/O Interface panels are available. Please contact the CTS sales team for more information

I/O InterfaceOrder NumberTypical Data Rate/Line VoltageTypical Shielding*

DB37, 1000pF pi Filter
3409-0012-13 Mbps / 100 VDC,
5 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

DB25, 1000pF pi Filter
3409-0009-13 Mbps / 100 VDC,
5 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

DB25, 100pF pi Filter
3409-0014-110 Mbps / 100 VDC,
5 Amps max
>50 dB from 0.5 to 2 GHz
>60 dB from 2 to 3 GHz
>60 dB from 3 to 6 GHz

DB9, 1000pF pi Filter
3409-0008-13 Mbps / 100 VDC,
5 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

DB9, 100pF pi Filter
3409-0010-110 Mbps / 100 VDC,
5 Amps max
>50 dB from 0.5 to 2 GHz
>60 dB from 2 to 3 GHz
>60 dB from 3 to 6 GHz

USB 2.0 Filter
3409-0018A-3480 Mbps / 5 V, 500 mA /
Max Current: 5A
>60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

USB 3.0 Filter(Active)
3409-0042A-15000 Mbps / 5 V, 900 mA /
Max Current: 1.5 A
>70 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>55 dB from 3 to 6 GHz

RJ-45 Filter
3409-0022A1 Gbit/s Copper-Line
Ethernet (1000 BASE-T)
>60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

DC Power Adaptor
3406-0004A50 VDC,
3 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>80 dB from 3 to 6 GHz

DC Power Adaptor,
Banana Jack Type
3406-0005A
3406-0006A
50 VDC,
10 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>80 dB from 3 to 6 GHz

AC Power Adaptor
3103-0009A250 VAC,
7 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>80 dB from 3 to 6 GHz

RF, N-SMA Connector
3408-0038>60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

RF, SMA-SMA Connector
3408-0039>60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

*SPECIFICATIONS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

  • Each shielding effectiveness is measured when each I/O interface panel, which is shown above, is mounted.
  • Above data was measured by Tescom, The Shielding Effectiveness might be different based on the measuring method and condition.
  • This data has been measured under the condition that the cables are not connected to each filters. When the cables are connected it can affect the shielding performance.