TC-5924AP Pneumatic Shield Box

The TC-5924AP Pneumatic Shield Box provides an efficient RF isolated test environment for testing mobile, WLAN and other small RF devices.

Request Quote Download Data Sheet

SKU: TC-5924AP Categories: , , Tag:

Description

TC-5924AP Pneumatic Shield Box Key Features

  • High RF Shielding
  • Pneumatic control of lid open-close and optional test fixture motions
  • EMI filters on all Data and DC lines
  • Easily customizable to meet various test needs
  • RS-232C Remote Control

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

Additional information

Weight 19 kg
Dimensions 11.4 × 10.6 × 4 in
Function

Pneumatic

Internal Depth

10-15in

Internal Height

0-6in

Internal Width

8-12in

Manufacturer

Tescom

Specifications

TC-5924AP Pneumatic Shield Box Specifications

  • RF Connectors without I/O interface panel: two(2) N (f) outside and SMA (f) inside
  • Line Voltage: 100-240 VAC, 50/60 Hz, 15 watt max.
  • Remote Control: RS-232C, 3 wire, DB9(s)
  • Air Connection
    • Main connector: 6mm OD hose, one-touch push-on fitting
    • Input air pressure: 5 to 10 bar
  • Dimension:
    • Inside: 270(W) x 290(D) x 103(H) mm
    • Outside: 330(W) x 401(D) x 208(H) mm, door closed.
    • 604(H) mm,  lid open.
  • Weight: approx. 19 kg
  • Packing
    • Size: 500(W) x 460(D) x 300(H) mm
    • Weight: approx. 23kg

    *The size or weight of a package may vary on how to pack a package.

Typical RF Shielding

TC-5924AP Pneumatic Shield Box Typical RF Shielding

The shielding effectiveness below is measured when the blank panel is mounted; other I/O interface panel results a different shielding effectiveness of the shield box.

Frequency Shielding effectiveness (dB)
100 to 2000 MHz > 80 dB
2000 to 3000 MHz > 80 dB
3000 to 6000 MHz > 70 dB
  • Each shielding effectiveness is measured when each I/O interface panel, which is shown above, is mounted.
  • Above data was measured by Tescom, The Shielding Effectiveness might be different based on the measuring method and condition.
  • This data has been measured under the condition that the cables are not connected to each filters. When the cables are connected it can affect the shielding performance.

Custom Configurations

TC Manual RF Shield Box Custom I/O Interface Panel

Customized I/O Interface panels are available. Please contact the CTS sales team for more information

[table id=2 /]

*SPECIFICATIONS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

  • Each shielding effectiveness is measured when each I/O interface panel, which is shown above, is mounted.
  • Above data was measured by Tescom, The Shielding Effectiveness might be different based on the measuring method and condition.
  • This data has been measured under the condition that the cables are not connected to each filters. When the cables are connected it can affect the shielding performance.