TC-5910D Manual RF Shield Box

TC-5910D provides RF shield and signal connections necessary for testing mobile wireless devices, such as mobile cell phones, RFID, Bluetooth or other small wireless devices. The TC-5910D RF Shield box has two RF ports and two EMI filtered data ports. With RF coupling accessories and filtered control ports, the TC-5910D makes an ideal solution for RF testing of mobiles, RFID or other small RF devices on test benches for R&D, Service, or QA.

Request Quote Download Data Sheet

SKU: TC-5910D Categories: , ,

Description

TC-5910D RF Shield Box Key Benefits

  • High RF Shielding
  • Manual Operation
  • Pneumatic version available
  • Small Foot Print
  • Easily Customizable IO Panel to meet RF testing needs

Pair the TC5910D RF Shield Box with antenna coupler and grid fixture for perfect setup for performing radiated(OTA) testing of your DUT.

Additional information

Weight 5 kg
Dimensions 9.25 × 5.1 × 5.4 in
Function

Manual

Internal Depth

0-10in

Internal Height

0-6in

Internal Width

0-8in

Manufacturer

Tescom

Specifications

TC-5910D Manual RF Shield Box Mechanical Specification

  • RF Shield Effectiveness: >70dB, DC ~ 2.5GHz *
  • Inner Dimension: 130(W) x 235(L) x 138(H) mm
  • Outer Dimension: 207W) x 424(L) x 170(H) mm, lid closed. 435(H)mm, lid open
  • Weight without accessories: 5 kg
  • Supplied with Test Report and RF Cable, RG-400S, N(m) to N(m) 1 m, 1 pc

*Effectiveness measured with connectors: RF (2 Type-N Female, SMA Female inside), Data (DB25 and DB9, RF Filtered, 100VDC, 3A Max) Optional USB 2.0 replacing standard DB9.

Typical RF Shielding

TC-5910D Manual RF Shield Box Typical RF Shielding

The shield effectiveness below is measured when the blank panel is mounted; other I/O interface panel results a different shielding effectiveness of the shield box.

  • 100 to 2000 MHz > 80 dB
  • 2000 to 3000 MHz > 70 dB
  • 3000 to 6000 MHz > 50 dB

***Isolation example above is based on I/O configuration as specified above. Isolation may be higher or lower based on specific I/O configuration installed.

Custom Configurations

TC Manual RF Shield Box Custom I/O Interface Panel

Customized I/O Interface panels are available. Please contact the CTS sales team for more information

I/O InterfaceOrder NumberTypical Data Rate/Line VoltageTypical Shielding*

DB37, 1000pF pi Filter
3409-0012-13 Mbps / 100 VDC,
5 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

DB25, 1000pF pi Filter
3409-0009-13 Mbps / 100 VDC,
5 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

DB25, 100pF pi Filter
3409-0014-110 Mbps / 100 VDC,
5 Amps max
>50 dB from 0.5 to 2 GHz
>60 dB from 2 to 3 GHz
>60 dB from 3 to 6 GHz

DB9, 1000pF pi Filter
3409-0008-13 Mbps / 100 VDC,
5 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

DB9, 100pF pi Filter
3409-0010-110 Mbps / 100 VDC,
5 Amps max
>50 dB from 0.5 to 2 GHz
>60 dB from 2 to 3 GHz
>60 dB from 3 to 6 GHz

USB 2.0 Filter
3409-0018A-3480 Mbps / 5 V, 500 mA /
Max Current: 5A
>60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

USB 3.0 Filter(Active)
3409-0042A-15000 Mbps / 5 V, 900 mA /
Max Current: 1.5 A
>70 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>55 dB from 3 to 6 GHz

RJ-45 Filter
3409-0022A1 Gbit/s Copper-Line
Ethernet (1000 BASE-T)
>60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

DC Power Adaptor
3406-0004A50 VDC,
3 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>80 dB from 3 to 6 GHz

DC Power Adaptor,
Banana Jack Type
3406-0005A
3406-0006A
50 VDC,
10 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>80 dB from 3 to 6 GHz

AC Power Adaptor
3103-0009A250 VAC,
7 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>80 dB from 3 to 6 GHz

RF, N-SMA Connector
3408-0038>60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

RF, SMA-SMA Connector
3408-0039>60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

*SPECIFICATIONS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

  • Each shielding effectiveness is measured when each I/O interface panel, which is shown above, is mounted.
  • Above data was measured by Tescom, The Shielding Effectiveness might be different based on the measuring method and condition.
  • This data has been measured under the condition that the cables are not connected to each filters. When the cables are connected it can affect the shielding performance.