TC-5955AP Pneumatic Shield Box

TC-5955AP Pneumatic Shield Box generates the Electro-Magnetic field for testing small RF devices such as Mobile Phones, Bluetooh, WLAN, Zigbee, etc. An external test signal applies through the inport port of TC-5955AP to generate a consistent and predictable test field inside. Its unique, compact and economical design is optimized for medium accuracy measurements.

Request Quote Download Data Sheet

SKU: TC-5955AP Category: Tag:

Description

Replaced by TC-5955APU

TC-5955AP Pneumatic Shield Box Key Benefits

  • Reliable High RF Shielding up to 6 GHz
  • Designed for long life
  • Specifically deisgned for various types of mobile phones
  • Pneumatic control of lid open-close
  • Absorbing materials for stable measurement results
  • EMI filters on all data ports and power line
  • RS-232C Remote Control

*SPECIFICATIONS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

Additional information

Weight 39 kg
Dimensions 16.7 × 13.7 × 16.7 in
Function

Pneumatic

Internal Depth

10-15in

Internal Height

10-20in

Internal Width

12-18in

Manufacturer

Tescom

Specifications

TC-5955AP Pneumatic Shield Box Specifications

  • Basic RF Connector: 16, N(f) outside to SMA (f) inside
  • Basic Data Connector: none
  • Remote Control: RS-232C, Dual Remote Switch
  • Air Connector:
    • Main Connector:6 mm OD hose, one-touch fitting
    • Input Air Pressure: 5 to 10 bar
  •  Dimensions
    • Outer Dimension: 534(W) x 526(D) x 583(H) mm Door Closed, 786(D) mm Door Open
    • Door Size:176(W) x 130(H) mm
    • Door Stroke (Open/Close): 260 mm
  • Weight: approx. 39 kg
  • Packing
    • Size: 676(W) x 636(D) x 699(H) mm
    • Weight: approx. 46 kg

*The size or weight of a package may vary on how to pack a package.

Typical RF Shielding

Typical RF Shielding

The shield effectiveness below is measured when the blank panel is mounted; other I/O interface panel results a different shielding effectiveness of the shield box.
  • 100 to 2000 MHz > 60 dB
  • 2000 to 3000 MHz > 60 dB
  • 3000 to 6000 MHz > 60 dB

Custom Configurations

TC Manual RF Shield Box Custom I/O Interface Panel

Customized I/O Interface panels are available. Please contact the CTS sales team for more information

I/O InterfaceOrder NumberTypical Data Rate/Line VoltageTypical Shielding*

DB37, 1000pF pi Filter
3409-0012-13 Mbps / 100 VDC,
5 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

DB25, 1000pF pi Filter
3409-0009-13 Mbps / 100 VDC,
5 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

DB25, 100pF pi Filter
3409-0014-110 Mbps / 100 VDC,
5 Amps max
>50 dB from 0.5 to 2 GHz
>60 dB from 2 to 3 GHz
>60 dB from 3 to 6 GHz

DB9, 1000pF pi Filter
3409-0008-13 Mbps / 100 VDC,
5 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

DB9, 100pF pi Filter
3409-0010-110 Mbps / 100 VDC,
5 Amps max
>50 dB from 0.5 to 2 GHz
>60 dB from 2 to 3 GHz
>60 dB from 3 to 6 GHz

USB 2.0 Filter
3409-0018A-3480 Mbps / 5 V, 500 mA /
Max Current: 5A
>60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

USB 3.0 Filter(Active)
3409-0042A-15000 Mbps / 5 V, 900 mA /
Max Current: 1.5 A
>70 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>55 dB from 3 to 6 GHz

RJ-45 Filter
3409-0022A1 Gbit/s Copper-Line
Ethernet (1000 BASE-T)
>60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

DC Power Adaptor
3406-0004A50 VDC,
3 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>80 dB from 3 to 6 GHz

DC Power Adaptor,
Banana Jack Type
3406-0005A
3406-0006A
50 VDC,
10 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>80 dB from 3 to 6 GHz

AC Power Adaptor
3103-0009A250 VAC,
7 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>80 dB from 3 to 6 GHz

RF, N-SMA Connector
3408-0038>60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

RF, SMA-SMA Connector
3408-0039>60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

*SPECIFICATIONS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

  • Each shielding effectiveness is measured when each I/O interface panel, which is shown above, is mounted.
  • Above data was measured by Tescom, The Shielding Effectiveness might be different based on the measuring method and condition.
  • This data has been measured under the condition that the cables are not connected to each filters. When the cables are connected it can affect the shielding performance.