Home » Products » TC-5922BP Pneumatic Shield Box
The TC-5922BP Shield Box provides an efficient RF isolated test environment for testing mobile, WLAN and other small RF devices. In addition of providing you two built-in SMA RF connectors, this box offers a choice of various optional IO modules to meet your product interface requirements The TC-5922 are available in various versions of closing mechanism from totally manual, electromagnetic, and pneumatic versions; as well as wider taller versions with ferrite absorber lining, so please call or submit the online form for further information.
Request Quote Download PDF
Size: |
11.6in x 17.1in x 9.4in (LxWxH) |
-
Key Features
-
Specifications
-
Typical RF Shielding
-
Customization Options
TC-5922BP Pneumatic Shield Box Key Features
- High RF Shielding
- Pneumatic control of lid open-close and optional test fixture motions
- EMI filters on all Data and DC lines
- Easily customizable to meet various test needs
- Red and Green LED's for Pass/Fail indication
- RS-232C Remote Control
TC-5922BP Pneumatic Shield Box Specifications
- RF Connectors without I/O interface panel: two(2) N (f) outside and SMA (f) inside
- Line Voltage: DC 24V, Max. 2A
- Remote Control: RS-232C, 3 wire, DB9(s)
- Air Connection
- Main connector: 6mm OD hose, one-touch push-on fitting
- Fixture control connector: 4mm OD hose, one-touch push-on fitting
- Input air pressure: 5 to 10 bar
- Dimension:
- Inside: 296W) x 435(D) x 238(H) mm
- Outside: 417(W) x 601(D) x 332(H) mm, lid closed.
- 623(H) mm, lid open.
- Weight: approx. 25 kg
- Packing
- Size: 560(W) x 820(D) x 470(H) mm
- Weight: approx. 29kg
*The size or weight of a package may vary on how to pack a package.
TC-5922BP Pneumatic Shield Box Typical RF Shielding
The shielding effectiveness below is measured when the blank panel is mounted; other I/O interface panel results a different shielding effectiveness of the shield box.
Frequency | Shielding effectiveness (dB) |
---|
100 to 2000 MHz | > 70 dB |
2000 to 3000 MHz | > 70 dB |
3000 to 6000 MHz | > 60 dB |
- Each shielding effectiveness is measured when each I/O interface panel, which is shown above, is mounted.
- Above data was measured by Tescom, The Shielding Effectiveness might be different based on the measuring method and condition.
- This data has been measured under the condition that the cables are not connected to each filters. When the cables are connected it can affect the shielding performance.
TC-5922BP Shield Box Custom I/O Interface Panel
Customized I/O Interface panels are available. Please contact the CTS sales team for more information[table id=2 /]
- Each shielding effectiveness is measured when each I/O interface panel, which is shown above, is mounted.
- Above data was measured by Tescom, The Shielding Effectiveness might be different based on the measuring method and condition.
- This data has been measured under the condition that the cables are not connected to each filters. When the cables are connected it can affect the shielding performance.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE
Dimensions |
11.6 x 17.1 x 9.2 in |