TC-5910B/C/D USED Manual RF Shield Box

Standard I/O Configuration of TC-5910B/C/D

  • 2xRF, 1xDB9, 1xDB25 -or-
  • 2xRF, 1xUSB, 1xDB25 -or-
  • Other options may be available upon request

*These RF shield boxes are available in limited quantity and are based on first serve basis.

Provides RF shield and signal connections necessary for testing mobile wireless devices, such as mobile cell phones. The TC-5910 RF Shield box now has a an optional I/O module that’s replaceable so it can be easily changed as your interface requirements change . With the RF coupling accessories and filtered control ports, the TC-5910 makes an ideal solution for RF testing mobiles and small RF devices on test benches for R&D, Service, and QA.

Request Quote Download Data Sheet

Model Number USED TC-5910DB/C/D
Size: 4.7 in x 8.8 in x 4.5 in (L x W x H)
Weight: 5 kg
  • Key Features
  • Mechanical Specifications
  • Typical RF Shielding
  • Customization Options

TC-5910D Manual RF Shield Box Key Features

  • High RF Shield Capabilities
  • Manual Operation
  • Pneumatic version available
  • Shock absorber on lid
  • Small Footprint
  • Easily Customizable to meet RF testing needs

TC-5910D Manual RF Shield Box Mechanical Specification

  • RF Shield Effectiveness: >70dB, DC ~ 2.5GHz *
  • Inner Dimension: 130(W) x 235(L) x 138(H) mm
  • Outer Dimension: 207W) x 424(L) x 170(H) mm, lid closed. 435(H)mm, lid open
  • Weight without accessories: 5 kg
  • Supplied with Test Report and RF Cable, RG-400S, N(m) to N(m) 1 m, 1 pc
*Effectiveness measured with connectors: RF (2 Type-N Female, SMA Female inside), Data (DB25 and DB9, RF Filtered, 100VDC, 3A Max) Optional USB 2.0 replacing standard DB9.

TC-5910D Manual RF Shield Box Typical RF Shielding

The shield effectiveness below is measured when the blank panel is mounted; other I/O interface panel results a different shielding effectiveness of the shield box.
  • 100 to 2000 MHz > 80 dB
  • 2000 to 3000 MHz > 70 dB
  • 3000 to 6000 MHz > 50 dB
***Isolation example above is based on I/O configuration as specified above. Isolation may be higher or lower based on specific I/O configuration installed.

TC-5910D Manual RF Shield Box Custom I/O Interface Panel

Customized I/O Interface panels are available. Please contact the CTS sales team for more information
I/O InterfaceOrder NumberTypical Data Rate/Line VoltageTypical Shielding*

DB37, 1000pF pi Filter
3409-0012-13 Mbps / 100 VDC,
5 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

DB25, 1000pF pi Filter
3409-0009-13 Mbps / 100 VDC,
5 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

DB25, 100pF pi Filter
3409-0014-110 Mbps / 100 VDC,
5 Amps max
>50 dB from 0.5 to 2 GHz
>60 dB from 2 to 3 GHz
>60 dB from 3 to 6 GHz

DB9, 1000pF pi Filter
3409-0008-13 Mbps / 100 VDC,
5 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

DB9, 100pF pi Filter
3409-0010-110 Mbps / 100 VDC,
5 Amps max
>50 dB from 0.5 to 2 GHz
>60 dB from 2 to 3 GHz
>60 dB from 3 to 6 GHz

USB 2.0 Filter
3409-0018A-3480 Mbps / 5 V, 500 mA /
Max Current: 5A
>60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

USB 3.0 Filter(Active)
3409-0042A-15000 Mbps / 5 V, 900 mA /
Max Current: 1.5 A
>70 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>55 dB from 3 to 6 GHz

RJ-45 Filter
3409-0022A1 Gbit/s Copper-Line
Ethernet (1000 BASE-T)
>60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

DC Power Adaptor
3406-0004A50 VDC,
3 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>80 dB from 3 to 6 GHz

DC Power Adaptor,
Banana Jack Type
3406-0005A
3406-0006A
50 VDC,
10 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>80 dB from 3 to 6 GHz

AC Power Adaptor
3103-0009A250 VAC,
7 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>80 dB from 3 to 6 GHz

RF, N-SMA Connector
3408-0038>60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

RF, SMA-SMA Connector
3408-0039>60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz
*SPECIFICATIONS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE
  • Each shielding effectiveness is measured when each I/O interface panel, which is shown above, is mounted.
  • Above data was measured by Tescom, The Shielding Effectiveness might be different based on the measuring method and condition.
  • This data has been measured under the condition that the cables are not connected to each filters. When the cables are connected it can affect the shielding performance.
Dimensions 4.7 x 8.8 x 4.5 in
<< return to products