TC-5972AP/CP Series RF Shield Box

TC-5972AP/CP RF Shield Box provides both high RF isolation and room for testing medium to large size wireless device testing. TC-5972AP/CP RF Shield Box is an ideal test platform for Engineering, Manufacturing, or service due to it’s ergonomic design. The TC-5972s are available in manual or pneumatic versions.

Request Quote Download Data Sheet

SKU: TC-5972AP/CP Categories: , , Tag:

Description

Shield Box TC-5972AP/CP Key Benefits

  • High RF shielding
  • Easy Opening/Closing of Door
  • 4 Standard RF Ports(N-Type Outside, SMA Inside)
  • EMI filters on all Data and DC lines
  • Installs up to Two Optional I/O Module Interfaces
  • Easily Field Replaceable Rear I/O modules

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

Additional information

Weight 38 kg
Dimensions 18.5 × 18.5 × 14.2 in
Function

Pneumatic

Internal Depth

15-20in

Internal Height

10-20in

Internal Width

18in and greater

Manufacturer

Tescom

Specifications

Shield Box TC-5972AP/CP Specifications

  • Shielding effectiveness:  >60dB DC~2.5GHz,  >50dB 2.5~6GHz
  • RF Connectors: 4 N(f) Outside and SMA(f) Inside
  • Data line Capacity: 100 VDC, 3 Amps maximum
  • Dimensions: Outer Dimension: 546(W)×620(D) ×444(H)mm
  • C Version Inner walls lined with ferrite absorber Inner Dimension: 470(W)×470(D) ×360(H)mm, 230(D)mm top side
  • Weight: 38Kg

Typical RF Shielding

Typical RF Shielding

The shield effectiveness below is measured when the blank panel is mounted; other I/O interface panel results a different shielding effectiveness of the shield box.
  • 100 to 2000 MHz > 70 dB
  • 2000 to 3000 MHz > 70 dB
  • 3000 to 6000 MHz > 50 dB

***Isolation example above is based on I/O configuration as specified above. Isolation may be higher or lower based on specific I/O configuration installed.

Custom Configurations

TC Manual RF Shield Box Custom I/O Interface Panel

Customized I/O Interface panels are available. Please contact the CTS sales team for more information

I/O InterfaceOrder NumberTypical Data Rate/Line VoltageTypical Shielding*

DB37, 1000pF pi Filter
3409-0012-13 Mbps / 100 VDC,
5 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

DB25, 1000pF pi Filter
3409-0009-13 Mbps / 100 VDC,
5 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

DB25, 100pF pi Filter
3409-0014-110 Mbps / 100 VDC,
5 Amps max
>50 dB from 0.5 to 2 GHz
>60 dB from 2 to 3 GHz
>60 dB from 3 to 6 GHz

DB9, 1000pF pi Filter
3409-0008-13 Mbps / 100 VDC,
5 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

DB9, 100pF pi Filter
3409-0010-110 Mbps / 100 VDC,
5 Amps max
>50 dB from 0.5 to 2 GHz
>60 dB from 2 to 3 GHz
>60 dB from 3 to 6 GHz

USB 2.0 Filter
3409-0018A-3480 Mbps / 5 V, 500 mA /
Max Current: 5A
>60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

USB 3.0 Filter(Active)
3409-0042A-15000 Mbps / 5 V, 900 mA /
Max Current: 1.5 A
>70 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>55 dB from 3 to 6 GHz

RJ-45 Filter
3409-0022A1 Gbit/s Copper-Line
Ethernet (1000 BASE-T)
>60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

DC Power Adaptor
3406-0004A50 VDC,
3 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>80 dB from 3 to 6 GHz

DC Power Adaptor,
Banana Jack Type
3406-0005A
3406-0006A
50 VDC,
10 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>80 dB from 3 to 6 GHz

AC Power Adaptor
3103-0009A250 VAC,
7 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>80 dB from 3 to 6 GHz

RF, N-SMA Connector
3408-0038>60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

RF, SMA-SMA Connector
3408-0039>60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

*SPECIFICATIONS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

  • Each shielding effectiveness is measured when each I/O interface panel, which is shown above, is mounted.
  • Above data was measured by Tescom, The Shielding Effectiveness might be different based on the measuring method and condition.
  • This data has been measured under the condition that the cables are not connected to each filters. When the cables are connected it can affect the shielding performance.