TC-5910D Manual RF Shield Box

TC-5910D provides RF shield and signal connections necessary for testing mobile wireless devices, such as mobile cell phones, RFID, Bluetooth or other small wireless devices. The TC-5910D RF Shield box has two RF ports and two EMI filtered data ports. With RF coupling accessories and filtered control ports, the TC-5910D makes an ideal solution for RF testing of mobiles, RFID or other small RF devices on test benches for R&D, Service, or QA.

Request Quote Download Data Sheet

SKU: TC-5910D Categories: , ,

Description

RF Shield Box TC-5910D Key Benefits

  • High RF Shield Capabilities
  • Manual Operation
  • Pneumatic version available
  • Small Foot Print
  • Easily Customizable to meet RF testing needs

Additional information

Weight 5 kg
Dimensions 9.25 × 5.1 × 5.4 in
Function

Manual

Internal Depth

0-10in

Internal Height

0-6in

Internal Width

0-8in

Manufacturer

Tescom

Specifications

TC-5910D Manual RF Shield Box Mechanical Specification

  • RF Shield Effectiveness: >70dB, DC ~ 2.5GHz *
  • Inner Dimension: 130(W) x 235(L) x 138(H) mm
  • Outer Dimension: 207W) x 424(L) x 170(H) mm, lid closed. 435(H)mm, lid open
  • Weight without accessories: 5 kg
  • Supplied with Test Report and RF Cable, RG-400S, N(m) to N(m) 1 m, 1 pc

*Effectiveness measured with connectors: RF (2 Type-N Female, SMA Female inside), Data (DB25 and DB9, RF Filtered, 100VDC, 3A Max) Optional USB 2.0 replacing standard DB9.

Typical RF Shielding

TC-5910D Manual RF Shield Box Typical RF Shielding

The shield effectiveness below is measured when the blank panel is mounted; other I/O interface panel results a different shielding effectiveness of the shield box.

  • 100 to 2000 MHz > 80 dB
  • 2000 to 3000 MHz > 70 dB
  • 3000 to 6000 MHz > 50 dB

***Isolation example above is based on I/O configuration as specified above. Isolation may be higher or lower based on specific I/O configuration installed.

Custom Configurations

TC Manual RF Shield Box Custom I/O Interface Panel

Customized I/O Interface panels are available. Please contact the CTS sales team for more information

I/O InterfaceOrder NumberTypical Data Rate/Line VoltageTypical Shielding*

DB37, 1000pF pi Filter
3409-0012-13 Mbps / 100 VDC,
5 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

DB25, 1000pF pi Filter
3409-0009-13 Mbps / 100 VDC,
5 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

DB25, 100pF pi Filter
3409-0014-110 Mbps / 100 VDC,
5 Amps max
>50 dB from 0.5 to 2 GHz
>60 dB from 2 to 3 GHz
>60 dB from 3 to 6 GHz

DB9, 1000pF pi Filter
3409-0008-13 Mbps / 100 VDC,
5 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

DB9, 100pF pi Filter
3409-0010-110 Mbps / 100 VDC,
5 Amps max
>50 dB from 0.5 to 2 GHz
>60 dB from 2 to 3 GHz
>60 dB from 3 to 6 GHz

USB 2.0 Filter
3409-0018A-3480 Mbps / 5 V, 500 mA /
Max Current: 5A
>60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

USB 3.0 Filter(Active)
3409-0042A-15000 Mbps / 5 V, 900 mA /
Max Current: 1.5 A
>70 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>55 dB from 3 to 6 GHz

RJ-45 Filter
3409-0022A1 Gbit/s Copper-Line
Ethernet (1000 BASE-T)
>60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

DC Power Adaptor
3406-0004A50 VDC,
3 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>80 dB from 3 to 6 GHz

DC Power Adaptor,
Banana Jack Type
3406-0005A
3406-0006A
50 VDC,
10 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>80 dB from 3 to 6 GHz

AC Power Adaptor
3103-0009A250 VAC,
7 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>80 dB from 3 to 6 GHz

RF, N-SMA Connector
3408-0038>60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

RF, SMA-SMA Connector
3408-0039>60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

*SPECIFICATIONS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

  • Each shielding effectiveness is measured when each I/O interface panel, which is shown above, is mounted.
  • Above data was measured by Tescom, The Shielding Effectiveness might be different based on the measuring method and condition.
  • This data has been measured under the condition that the cables are not connected to each filters. When the cables are connected it can affect the shielding performance.